ARIZONA PUBLISHES CODE FOR GUIDANCE IN BUILDING DAMS

Share:
Arizona has approved a new 30,000-word building code designed to guide engineers in the safe and stable construction of dams using modern, flexible standards. The code outlines specific regulations for critical structural elements, including foundations, spillways, arch dams, and gravity concrete dams. It aims to ensure uniform safety while remaining open to future technological advancements and innovative engineering designs.

Featured in the January 1933 Issue of Arizona Highways

BY: M. G. Holt

Arizona Publishes Code For Guidance In Building Dams

Courtesy Engineering News-Record

Regulations for the design and construction of dams in Arizona have been approved by the state engineer in the form of a 30,000-word building code. The bulletin supplements one issued in 1929 that outlined the required procedure for making application for approval of plans and specifications in accordance with the laws of that year covering state regulations. The code was prepared by J. A. Fraps, engineer in charge of dams, under the general supervision of T. S. O'Connell, state engineer.

According to the foreword of the code, the purpose is "to compile pertinent sound data relative to design and construction, in the belief that such procedure will eventually result in dams of uniform safety and stability." It states, further, "this office has no desire to design dams, and is not entitled to do so under the authority granted by House Bill No. 188, but considers it necessary, from the viewpoint of efficient regulation, to issue a code for the guidance of the designing engineer. Certain theories of design have become obsolete in recent years, and have become superseded by more exact theories. Use of old methods of design can be thwarted by the issuance of a code which definitely states the methods of design considered adequate, and thereby secure more efficient and safer regulation. Construction methods also change, and experience often indicates that improper methods have been used in the past. A good design is worthless unless the structure is built in such manner as to secure the results contemplated in the design. This circular cannot attempt to include detailed specifications for the construction of all types of dams, but will set forth main items in a general way, which must be covered in detail by the specifications prepared by the applicant.

"This code for dams is not considered to be irrevocable. There are numerous features connected with design and construction that are considered questionable and should be left open to discussion. In such cases the state must necessarily be conservative, and the code may be more exacting in certain regards than might be desired by the designer or builder. The code is presumed to be flexible, however, and changes in design and construction will be inculcated as generally accepted theory and practice dictate.

New designs, differing widely from those discussed herein, are not discouraged. They will receive the attention of this office, and are welcome, for new designs, embodying sound engineering principles, and resulting in more economical structures, are needed for the development of power and irrigation projects."

Foundation and Spillways.

Taking up first the matter of foundations, the code covers the subject first in general and then treats specifically the requirements for various types of structures. The section emphasizes the need for adequate foundations as the first assurance of safety in dam building and emphasizes the need for exploration and the possibility that geological advice may be needed. Preparation of the rock foundation for concrete dams is outlined in some detail covering care in blasting, stepping of the foundation and cleaning. The section concludes with the rule that no concrete shall be placed on foundations or abutment rock until written approval of the state engineer has been secured.

On the subject of spillways, reference is made to inadequate spillways as a common source of dam failures and emphasizes the particular need for sufficient capacity in connection with earth and rock fill dams where overtopping is serious. No quantities of runoff per unit of catchment area are given in the code, and the general requirement is that the spillway shall pass the maximum probable flood. A minimum freeboard of 3 feet is established, and a formula provides for the calculation of freeboards, based on the length of the reservoir, which introduces the factor of wave size. Spillway gates are subject to the supervision and control of the state office. Proof of the functioning of automatic gates is placed on the applicant, and the final classification is to be decided by the state engineer.

Arch Dams

In view of unknown factors in connection with definite analysis of arch-dam stresses, the code does not fix rules pertaining to arch design. The statements cover the principal elements of accepted practice and the hope is expressed that they can be superseded soon when design methods have become more exact. Arch dams designed by the application of the cylinder formula will not be considered. The design method of the U. S. Bureau of Reclamation in the distribution of loads between arch and cantilever is considered acceptable.

Gravity Concrete Dams

"At the present time authorities disagree about the forces to be considered in hydrostatic uplift under a gravity dam." The code requirements, in the case of a positive system of drains, is for full uplift to be assumed upstream from the drains, and uplift equal to maximum backwater to be assumed over the remainder of the area. When drains are omitted a gravity dam shall be designed on the assumption that uplifts vary uniformly 75 per cent of full hydrostatic pressure at the upstream face to tailwater head at the downstream face. The code suggests that possible modifications of uplift provisions may be made when future investigations permit of more accurate estimate of upward pressures.

"The sliding factor has been given a great deal of attention in the past, but will not be a vital requirement of this office. It will be the policy of this office to lay great stress on proper foundation materials, preparation of foundations, including stepping and placing of foundation concrete. If these requirements are satisfied in every particular, this office will not be exacting in the requirement of a low sliding factor."

Concrete

The weight figure of concrete is to be taken at 145 lb. per cu. ft., unless tests with material to be used in the structure indicate a different weight. Qualities of weather resistance, low shrinkage and imperviousness are stressed for concrete to be used in dams. Regarding heat of hydration, the code mentions the possibility of using a low-heat cement, leaving sections of the dam open temporarily to facilitate dissipation of heat. It closes by stating that the "entire problem is not fully solved and should receive further attention from designers and builders."

On the subject of stress allowance, a maximum figure of 50 lb. for concrete